Renesas Electronics /R7FA6M4AF /SCI3 /SSR_MANC

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as SSR_MANC

7 43 0 0 00 0 0 0 0 0 0 0 0 (0)MER 0 (0)MPB 0 (0)TEND 0 (0)PER 0 (0)FER 0 (0)ORER 0 (0)RDRF 0 (0)TDRE

FER=0, TDRE=0, PER=0, MER=0, MPB=0, RDRF=0, TEND=0, ORER=0

Description

Serial Status Register for Manchester Mode (SCMR.SMIF = 0, and MMR.MANEN = 1)

Fields

MER

Manchester Error Flag

0 (0): No Manchester error occurred

1 (1): Manchester error has occurred

MPB

Multi-Processor

0 (0): Data transmission cycles

1 (1): ID transmission cycles

TEND

Transmit End Flag

0 (0): A character is being transmitted

1 (1): Character transfer has been completed.

PER

Parity Error Flag

0 (0): No parity error occurred

1 (1): A parity error has occurred

FER

Framing Error Flag

0 (0): No framing error occurred

1 (1): A framing error has occurred

ORER

Overrun Error Flag

0 (0): No overrun error occurred

1 (1): An overrun error has occurred

RDRF

Receive Data Full Flag

0 (0): No received data is in RDR register

1 (1): Received data is in RDR register

TDRE

Transmit Data Empty Flag

0 (0): Transmit data is in TDR register

1 (1): No transmit data is in TDR register

Links

() ()